AEROSOL SCIENCE · EXPOSURE · INDOOR ENVIRONMENTS

Aerosol House Lab.

One source. Connected rooms. A shared atmosphere.

Explore how airborne particles and gases spread through a fictional four-bedroom, two-storey UK mid-terraced home—and how ventilation changes the picture.

Educational simulation · not live sensors. Room colours represent modelled concentrations. Read assumptions ↓

AEROSOL HOUSE LAB

Simulation dashboard

Paused30 min0.3 ACH4 occupants

02 / FOLLOW THE AIR

House map

30 min

REAR GARDEN ↑ · shared party walls on both sides · street frontage ↓

First floor 4 bedrooms

Ground floor living spaces

Concentration

Each room has one colour for its modelled concentration. The scale stays fixed for the selected measurement, with more colour detail at low concentrations. Values above the upper tick use the warmest colour. Select a room for its readings and settings.

04 / COMPARE MITIGATION

Ventilation comparison

Same source, doors, occupants and HEPA settings in both runs; only outdoor air exchange changes. Cumulative inhaled amount assumes 0.5 m³/h breathing in the selected room for the full elapsed time. Not a health dose limit or an individual’s movement history.

05 / WATCH THE TRAJECTORY

Room concentration over time

━ Current ventilation┄ No outdoor ventilation

All-room sensor readings 10 zones · selected time
Simulated readings at 30 minutes
RoomPeople°C% RHPM₁
µg/m³
PM₂.₅
µg/m³
PM₁₀
µg/m³
CO₂
ppm
CO
ppm
VOC surrogate
µg/m³
Tracer
a.u./m³
Sound
dB(A)

MODEL, ASSUMPTIONS & EVIDENCE

Make the assumptions visible.

A room is a mixed-air zone.

Ten zones, 124 m² floor area, 2.4 m ceilings and 297.6 m³ total air volume. Four bedrooms upstairs; hall and landing link the floors. Volumes and flows are illustrative, not a survey of a particular house.

Vᵢ dCᵢ/dt = Sᵢ + ΣQᵢⱼ(Cⱼ − Cᵢ) + ACH·Vᵢ(Cout − Cᵢ) − (kdep·Vᵢ + CADRᵢ)Cᵢ.

Symmetric room exchanges are 30 m³/h through open doors, 2.4 m³/h through closed-door leakage and 45 m³/h on the staircase before temperature adjustment. These assumed mixing exchanges conserve transported mass. We do not solve pressure, wind, directional stack flows or plumes. No transfer through party walls is modelled.

Temperature & humidity: sensitivity, not certainty.

Temperature differences multiply assumed inter-room exchange by 1 + 0.04|ΔT|. This is a user-explorable sensitivity parameter, not a validated buoyancy law.

RH scales particle deposition by [1 + 0.3·RH/(1−RH)]⅔ using an illustrative hygroscopic-growth assumption (RH as fraction). Base dry-bin deposition is 0.12, 0.4 and 1.5 h⁻¹; tracer deposition is 0.2 h⁻¹. Mass cut-offs remain dry-equivalent; wet optical-sensor response and viral survival are not predicted.

Gas concentrations are unaffected by this RH deposition rule. VOC chemistry, sorption, humidity dynamics and microbial inactivation are excluded.

Illustrative sources, reproducible runs.

PM bins are non-overlapping internally; displayed PM₁, PM₂.₅ and PM₁₀ are cumulative. No ultrafine particle count is inferred. CO₂ begins at 420 ppm, other gases at zero; outdoor PM is an editable dry-mass boundary. No noise or real sensor feed is added.

Time step: 15 seconds, explicit mass-balance integration, horizon 120 minutes. CO and VOC are passive scalar surrogates; source magnitudes are hypothetical, not measured appliance emissions. No pathogen-specific infectivity or exposure thresholds are used.

Read the underlying science.

References support general principles, not the app’s numerical defaults or validation.

Turn an exposure question into a research tool.

This is a demo version. For the full version or a customised application, get in touch.